National standard titration method water quality online monitoring instrument

Online monitoring device for water alkalinity (methyl orange alkalinity).

Online monitoring device for water quality alkalinity (full alkalinity).

Online chloride ion monitor

Online water hardness monitoring instrument

Online monitoring instrument for water hardness (high concentration).

Online calcium hard monitoring device

Online sulfate monitoring instrument

Online Methyl Orange Acidity Monitor

Online Phenolphthalein Acidity Monitoring Instrument

Permanganate index water quality online monitor
Service Hotline
+86-0632-2723255 +8618363281129
The device is an online analyzer that uses titration colorimetric experiments to automatically determine water hardness. Reagents are added to the water sample using a peristaltic pump, causing a color reaction. The instrument calculates the concentration of water hardness by assessing the intensity of the color or determining at which value the color changes. The measurement range of the instrument depends on the type of reagent.
This analyzer can operate automatically and continuously for long-term unattended operation according to on-site settings, and is widely applicable to natural water, cooling water, softened water, H-type cation exchanger effluent, boiler water, industrial circulating water, and other scenarios. Depending on the complexity of on-site testing conditions, appropriate pretreatment systems can be selected to ensure reliable testing processes and accurate results, fully meeting the needs of different on-site scenarios.
Technical Specifications |
|
Measurement methods | Titration colorimetry |
Measurement range | 0.094 - 3.752mmol/L 0.141 - 5.632mmol/L |
Measurement cycle | Minimum test cycle is 3 minutes |
Precision | ≤ 5% F.S. Use a 50% range standard solution |
Lower detection limit | 0.094 |
Application industries | Natural water, cooling water, softened water, H-type cation exchanger effluent, boiler water, industrial circulating water |
Sampling cycle | Time interval (adjustable), hour, or trigger measurement mode, all configurable |
Calibration cycle | Automatic calibration (adjustable within 1~99 days), manual calibration can be set according to actual water samples |
Maintenance cycle | Maintenance intervals should be longer than 2 months, with each session lasting about 30 minutes |
Human-machine operation | Touchscreen display and command input |
Self-inspection and protection | The instrument self-diagnoses its operating status, ensuring no data loss after abnormalities or power outages; After abnormal reset or power is cut off and power is restored, the instrument automatically removes residual reactants and resumes operation |
Data storage | No less than half a year of data storage |
Power supply | AC230±10%V,50~60Hz,5A |
Work environment | For indoor operation, recommended temperature 5~28°C, humidity ≤90% (non-condensing) |
Inches | 470x370x180 mm |