Language

Product Center

Residual chlorine meter sensor

Product list

Recommended Products

1/1
Water Quality Analysis — Residual Chlorine Controller
  • Model
  • Applicable IndustriesSuitable for water quality monitoring in swimming pool monitoring, municipal sewage, waterworks, petrochemical industry, secondary water supply, etc
  • CategoryResidual chlorine meter sensor
  • Product FeaturesSet parameters | Protective casing | Robust circuit | ICD high-brightness backlight | Precise and stable | Multiple outputs
after-sales service

Service Hotline

+86-0632-2723255 +8618363281129

Consult immediately
Product Introduction

• LCD display with orange backlight, English user interface

• Calibration and settings can be password protected

• Technical parameters can be set on-site using buttons

• High stability and high precision, capable of measuring residual chlorine and temperature

• Multiple output modes (relay, 4-20 mA, RS485)

• Ultra-strong anti-interference circuit design, suitable for on-site installation in areas with strong electromagnetic interference

• After power outage, setting parameters and calibration data are not lost. It supports manual setting/automatic temperature compensation process temperature and calibration temperature. When the temperature electrode is damaged, the system switches from automatic temperature compensation to manual temperature compensation, allowing online calibration of test data

• Application areas: residual chlorine monitoring in drinking water, swimming pools, food hygiene, industrial process water disinfection, and reverse osmosis membranes in industrial water

Performance Parameters

Measurement range
, resolution
, measurement accuracy

FCL:0.00-20.00ppm ,HOCL:0.00-20.00ppm
FCL:0.01ppm ,          HOCL:0.01ppm

FCL:±0.05ppm ,       HOCL:±0.05ppm

Temperature compensation method,
temperature measurement range,
temperature compensation range,
temperature resolution,
temperature accuracy,
electrode current measurement range
, electrode current measurement accuracy,
polarization voltage range,
working environment temperature,

Display:
Residual chlorine current output
Temperature current output 1
. Current output accuracy 2.
RS485
Communication rate
: Relay contact capacity
Cleaning set
for a multifunctional relay
Relay delay operation
data recording
Language selection
Protection level Power
supply
Installation method
Weight

Pt-1000/NTC22K
-10.0"C~130.0"C
-10.0"C~130.0"C
0.1"C
+0.2'C
-5.0nA~1500 nA
±0.5nA
0~-1000mV
0°C ~70°C
-20°C ~70°
C Backlit ultra-large dot matrix LCD
isolated 4~20mA output, maximum load 500Ω
isolated 4~20mA output, maximum load 500Ω
±0.05 mA
Mod bus RTU standard protocol
9600/19200/38400
5A/250VAC, 5A/30VDC
ON: 1~1000 seconds, OFF: 0.1~1000.0 hours
cleaning/cycle alarm/error alarm
0~120 seconds
, 500,000 entries
English/Traditional Chinese/Chinese Simplified
IP65
90~260VAC, power consumption <5W
, panel mount/wall-mount/pipeline
installation: 0.85Kg

Online Message
  • Your name:

  • Contact number:

  • Message content:

  • CAPTCHA:

Home Product Center Solution Operation Services Project Case About Us News Contact Us

Copyright © Mozhidao (shandong) Measurement & Control Equipment Co,Ltd

Address:No. 267, 2nd Floor, East District, Zhimao City, Honghe Road, Jinghe Street, Tengzhou City, Zaozhuang City, Shandong Province

Email:mzd18363281129@163.com

Technical Support:tengzhou.com.cn

Service Hotline

+86-0632-2723255

+8618363281129

Welcome to call for negotiation and consultation

WeChat Official Account

Tiktok